• (0)

ACTI9 IPRD65R MODULAR SURGE ARRESTER 1P+N 350V W/REMOTE TRANSFERT

A9L65501
2124280

Sign in to view price

This Acti9 iPRD65r surge arrester protects 1P+N installations. It allows quick replacement of damaged cartridges. This Type 2 device is recommended for very high risk level and incoming panel board. It offers remote reporting of the "cartridge must be changed" message. It can be turned over to allow the phase/neutral/earth cables to enter through either the top or the bottom. The associated circuit breaker Isc breaking capacity can go up to 50kA. It is compatible with TT and TN-S earthing system. The Uc maximum continuous operating voltage in common mode is 260VAC between neutral and earth, and 350VAC between phase and earth. The Uc maximum continuous operating voltage in differential mode (between phase and neutral) is 350VAC. The Up Voltage protection level is 1.5kV in common mode (N/PE) and in differential mode (L/N). The Ue rated operational voltage is 230VAC +/- 10%. The product colour is white (RAL9003).The dimensions are (W) 36mm x (H) 85mm x (D) 69mm. The weight is 238g. The degree of protection is IP20 and IP40 in modular enclosure. The operating temperature is -25°C to 60°C. The storage temperature is -40°C to 85°C. This product is compliant with EN 61643-11 and IEC 61643-11 standards.
SCHNEIDER-A9L65501_PEP1
schneider-a9l65501
  • All returns must be made within 7 days of purchase.
  • Valid receipt is required for all returns.
  • Click Here to view the return policy.
Available Shipping Methods:

Product Overview

Product ID:
2124280
Manufacturer Part Number:
A9L65501
EAN:
3606480506291
Brand/Manufacturer
SCHNEIDER ELECTRIC
Unit of Measure:
PCS

Specification

Category type 2:
yes
Construction size:
4 modular spacing
Degree of protection (IP):
IP20
Integrated backup fuse:
no
Max. PV-voltage:
0 V
Max. conductor cross section flexible (fine-strand):
35 mm²
Max. conductor cross section solid (solid, stranded):
35 mm²
Max. continuous voltage AC:
350 V
Max. continuous voltage DC:
0 V
Max. discharge surge current (8/20):
65 kA
Mounting method:
DIN rail (top hat rail) 35 mm
Nominal discharge surge current (8/20):
20 kA
Nominal voltage AC:
350 V
Nominal voltage DC:
0 V
Number of conductors (without earthing):
1
Signalling at the device:
Optical
System configuration TN-S:
yes
System configuration TT:
yes
Voltage protection level:
1.5 kV
Voltage protection level L-N:
1.5 kV
Voltage protection level N-PE:
1.5 kV
With remote signalling contact:
yes