ACTI9 IPRD40 MODULAR SURGE ARRESTER 3P+N 350V

A9L40600
2149055

Sign in to view price

This Acti9 iPRD40 surge arrester protects 3P+N installations. It allows quick replacement of damaged cartridges. This Type 2 device is recommended for high risk level and incoming panel board. It can be turned over to allow the phase/neutral/earth cables to enter through either the top or the bottom. The associated circuit breaker Isc breaking capacity can go up to 50kA. This Acti9 iPRD40 is compatible with TT and TN-S earthing system. The Imax rated discharge current is 40kA. The In nominal discharge current is 15kA. The Uc maximum continuous operating voltage in common mode is 260VAC between neutral and earth, and 350VAC between phase and earth. The Uc maximum continuous operating voltage in differential mode (between phase and neutral) is 350VAC. The Up Voltage protection level is 1.4kV in common mode (N/PE) and in differential mode (L/N). The Un rated service voltage is 230VAC or 400VAC. The operating frequency is 50Hz or 60Hz. The dimensions are (W) 72mm x (H) 85mm x (D) 69mm. The width in 9mm pitches is 8. The weight is 450g. The degree of protection is IP20 and IP40 in modular enclosure. The operating temperature is -25°C to 60°C. The storage temperature is -40°C to 85°C. This product is compliant with EN 61643-11 and IEC 61643-11 standards.
SCHNEIDER-A9L40600_PEP1
schneider-a9l40600
  • All returns must be made within 7 days of purchase.
  • Valid receipt is required for all returns.
  • Click Here to view the return policy.
Available Shipping Methods:

Product Overview

Product ID:
2149055
Manufacturer Part Number:
A9L40600
EAN:
3606480506383
Brand/Manufacturer
SCHNEIDER ELECTRIC
Unit of Measure:
PCS

Specification

Category type 2:
yes
Construction size:
8 modular spacing
Degree of protection (IP):
IP20
Integrated backup fuse:
no
Max. PV-voltage:
0 V
Max. conductor cross section flexible (fine-strand):
35 mm²
Max. conductor cross section solid (solid, stranded):
35 mm²
Max. continuous voltage AC:
350 V
Max. continuous voltage DC:
0 V
Max. discharge surge current (8/20):
40 kA
Mounting method:
DIN rail (top hat rail) 35 mm
Nominal discharge surge current (8/20):
15 kA
Nominal voltage AC:
350 V
Nominal voltage DC:
0 V
Number of conductors (without earthing):
3
Short-circuit breaking capacity (Isccr):
0 kA
Signalling at the device:
Optical
System configuration DC:
no
System configuration IT:
no
System configuration TN:
no
System configuration TN-C:
no
System configuration TN-C-S:
no
System configuration TN-S:
yes
System configuration TT:
yes
System configuration other:
no
Voltage protection level:
1.4 kV
Voltage protection level L-N:
1.4 kV
Voltage protection level N-PE:
1.4 kV
With remote signalling contact:
no