• (0)

ACTI9 IPF K 20 MODULAR SURGE ARRESTER 3P+N 340V

A9L15693
2007743

Sign in to view price

This Acti9 iPF K 20 product is a modular surge arrester. It protects 3P+N installations. The Imax maximum discharge current is 20kA .The In nominal discharge current is 5kA. The multi-pole single-piece surge arrester range is adapted for TT, TN-S, TN-C earthing systems. This type 2 incoming protection surge arrester is recommended for a medium risk level. The Uc maximum continuous operating voltage in common mode is 260VAC between neutral and earth, and is 340VAC between phase and earth. The Uc maximum continuous operating voltage in differential mode (between phase and neutral) is 340VAC. The Up Voltage protection level is 1.5kV in common mode (between neutral and earth) and is 1.1kV in differential mode (between phase and neutral). The Ue rated operational voltage is 230VAC or 400VAC +/- 10%. The product colour is white (RAL9003).The dimensions are (W) 72mm x (H) 81mm x (D) 69mm. The weight is 420g. The degree of protection is IP20 and IP40 in modular enclosure. The operating temperature is -25°C to 60°C. The storage temperature is -40°C to 85°C. This product is compliant with IEC 61643-11 and EN 61643-11 standards.
SCHNEIDER-A9L15693_PEP1
schneider-A9L15693
  • All returns must be made within 7 days of purchase.
  • Valid receipt is required for all returns.
  • Click Here to view the return policy.
Available Shipping Methods:

Product Overview

Product ID:
2007743
Manufacturer Part Number:
A9L15693
EAN:
3606480089947
Brand/Manufacturer
SCHNEIDER ELECTRIC
Unit of Measure:
PCS

Specification

Category type 2:
yes
Construction size:
8 modular spacing
Degree of protection (IP):
IP20
Integrated backup fuse:
no
Integrated short-circuit protection:
no
Leakage-current free:
no
Max. PV-voltage:
0 V
Max. conductor cross section flexible (fine-strand):
16 mm²
Max. conductor cross section solid (solid, stranded):
16 mm²
Max. continuous voltage AC:
340 V
Max. continuous voltage DC:
0 V
Max. discharge surge current (8/20):
20 kA
Max. overcurrent protection device, parallel connection (fuse):
40 A
Max. overcurrent protection device, series connection (fuse):
40 A
Mounting method:
DIN rail (top hat rail) 35 mm
Nominal discharge surge current (8/20):
5 kA
Nominal voltage AC:
400 V
Nominal voltage DC:
0 V
Number of conductors (without earthing):
3
Short-circuit breaking capacity (Isccr):
25 kA
Signalling at the device:
Optical
System configuration DC:
no
System configuration IT:
no
System configuration TN:
no
System configuration TN-C:
no
System configuration TN-C-S:
no
System configuration TN-S:
yes
System configuration TT:
yes
System configuration other:
no
Voltage protection level:
1.1 kV
Voltage protection level L-N:
1.1 kV
Voltage protection level N-PE:
1.5 kV
With remote signalling contact:
no