• (0)

ALTIVAR 610 VARIABLE SPEED DRIVE IP20 132KW 380/415V

ATV610C13N4
2224632

Sign in to view price

IP 20 frequency inverter for three-phase asynchronous motors, specially designed for pump and fan applications in the following market segments: Water & Wastewater, Oil & Gas, building management and energy plant.
schneider-atv610c13n4_PEP1
schneider-ATV610C13N4-datasheet1
  • All returns must be made within 7 days of purchase.
  • Valid receipt is required for all returns.
  • Click Here to view the return policy.
Available Shipping Methods:

Product Overview

Product ID:
2224632
Manufacturer Part Number:
ATV610C13N4
EAN:
3606480700668
Brand/Manufacturer
SCHNEIDER ELECTRIC
Unit of Measure:
PCS

Specification

4-quadrant operation possible:
yes
Application in domestic- and commercial area permitted:
yes
Application in industrial area permitted:
yes
Degree of protection (IP):
IP20
Depth:
390 mm
Height:
852 mm
Integrated breaking resistance:
no
Mains frequency:
50/60 Hz
Mains voltage:
380...415 V
Max. output at linear load at rated output voltage:
132 kW
Max. output at quadratic load at rated output voltage:
132 kW
Max. output frequency:
500 Hz
Max. output voltage:
415 V
Nominal output current I2N:
250 A
Number of HW-interfaces RS-232:
0
Number of HW-interfaces RS-422:
0
Number of HW-interfaces RS-485:
1
Number of HW-interfaces USB:
0
Number of HW-interfaces industrial Ethernet:
0
Number of HW-interfaces other:
0
Number of HW-interfaces parallel:
0
Number of HW-interfaces serial TTY:
0
Number of analogue inputs:
3
Number of analogue outputs:
2
Number of digital inputs:
6
Number of digital outputs:
0
Number of interfaces PROFINET:
0
Number of phases input:
3
Number of phases output:
3
Relative symmetric net frequency tolerance:
5 %
Relative symmetric net voltage tolerance:
10 %
Supporting protocol for AS-Interface Safety at Work:
no
Supporting protocol for ASI:
no
Supporting protocol for BACnet:
no
Supporting protocol for CAN:
no
Supporting protocol for Data-Highway:
no
Supporting protocol for DeviceNet:
no
Supporting protocol for DeviceNet Safety:
no
Supporting protocol for EtherNet/IP:
no
Supporting protocol for Foundation Fieldbus:
no
Supporting protocol for INTERBUS:
no
Supporting protocol for INTERBUS-Safety:
no
Supporting protocol for KNX:
no
Supporting protocol for LON:
no
Supporting protocol for MODBUS:
yes
Supporting protocol for PROFIBUS:
no
Supporting protocol for PROFINET CBA:
no
Supporting protocol for PROFINET IO:
no
Supporting protocol for PROFIsafe:
no
Supporting protocol for SERCOS:
no
Supporting protocol for SUCONET:
no
Supporting protocol for SafetyBUS p:
no
Supporting protocol for TCP/IP:
no
Supporting protocol for other bus systems:
no
Type of converter:
U converter
Width:
320 mm
With PC connection:
no
With control element:
yes
With optical interface:
no

Reviews

We'd like your opinion! Rate and review this item

There are no reviews from other users.

Recently Viewed

View All